Your Position: Home - Wire Mesh - Installation and Choosing Tips of Gabions and Chicken Wire
The Limitations of Gabion Walls
Kuojiu are exported all over the world and different industries with quality first. Our belief is to provide our customers with more and better high value-added products. Let's create a better future together.
The design of gabion wall should be calculated on the perception of most soil pressure slope; here are limitations when design gabion walls must adhere to.
Gabions of galvanized wire boxes, with a P. V. C. coating ( coating of polyvinyl chloride ) are commonly used for river re-shaping in bridge and other construction projects. Green coating and grey coating at customers request.
Grey coated galvanized gabion box wire mesh
Mesh size:100mmx120mm
Finish: Grey coating after zinc coating
Wire:BS - standard tensile strength of not less than 350 Mpa.
Gabion Basket-PVC/Galvanised-Green Coated Galvanized Gabion Mesh
Specification:
PARTITION: 1
ZINC COAT: 260G/M2
MESH WIRE: 2.7MM
TIE WIRE: 2.2MM
MESH OPEN: 80MM x 100mm
SELVEDGE WIRE: 4.0MM
TENSILE STRNGHT: 380-550N/M2
Technical details of gabions material suitable river bank protection work
Technical details of Gabions wire, galvanizing, galvanised wire with P.V. C. coating ( properties including tensile strength, elongation, salt water exposure, durometer hardness, creeping resistance, resistance to abrasion and more tests), gabion mesh, selvedges, Diaphragms and End-Panels, binding and connecting wire, filling material, tolerances on wire diameter applied and gabions dimension.
.
1.1. General Introduction
The requirements as set out below for Gabions shall also apply to mattresses.
The gabions shall be flexible P.V.C. coated and galvanised wire boxes of the sizes stated and in this Specification fabricated of wire mesh of the type and size, and selvedged as specified below.
Each gabion shall be divided by diaphragms into cells whose length shall not be greater than the width of the gabion plus 100 millimetres, except in the case of 1.5 metre long by 1 metre wide gabions which have no diaphragm, 2.5 metre long by 1 metre wide gabions which shall have one central diaphragm, and Reno mattresses where the diaphragms shall have a maximum spacing of 600 mm.
1.2. Wire
All wire used in fabrication of the gabions and in the wiring operations during construction shall conform to BS - having a tensile strength of not less than 350 Mpa.
Unless stated otherwise on the Drawings or in any Special Provisions Addendum to this Specification, the wire used shall be 2.7 mm diameter, galvanised. The wire shall be PVC coated in accordance the specifications.
1.3. Galvanising
All wire used in the fabrication of the gabions and in the wiring operations during construction shall be galvanised to BS 443- and the minimum weight of the zinc coating shall be according to the figures shown in the table below;
Diameter of Wire (mm)
Weight of Coating (grams/sq.metre)
3.9
290
3.4
275
3.0
275
2.7
If you are looking for more details, kindly visit Pvc Coated Gabion Box.
Recommended article:260
2.4
260
2.2
240
2.0
240
The adhesion of the zinc coating to the wire shall be such that when the
wire is wrapped six turns round a mandrel of 4 times the diameter of
the wire, it shall not flake nor crack to such an extent that any zinc can
be removed by rubbing with the bare fingers.
1.4. P.V.C. Coating.
All wire used in the fabrication of the gabions and in the wiring operations during construction shall, after galvanising, have extruded on to it a coating of polyvinyl chloride, or PVC.
The coating shall be grey in colour, or dark green at options, in an average thickness of 0.55 mm and nowhere be less than 0.40 mm in thickness and shall be capable of resisting eleterious effects of natural weather exposure, immersion in salt water and shall not show any material difference in its initial properties listed below:
Initial Properties
(a) Specific Gravity
1.30 to 1.35, in accordance with ASTM D792-66(79)
(b) Durometer Hardness
50 to 60 shore D units in accordance with ASTM D-76 (ISO 868-)
(c) Volatile Loss
At C for 24 hours - shall not be greater than 2%,
At C for 240 hours - shall not be greater than 6%,
in accordance with ASTM -67(74) (ISO 176-) and ASTM D-78
(d) Tensile Strength
210 Kg/cm2 in accordance with ASTM D412-75
(e) Elongation
Not less than 200% and not greater than 280% in accordance with ASTM D412-75
(f) Modulus of Elasticity
At 100% elongation:- not less than 190 Kg/cm2 in accordance with ASTM D412-75
(g) Resistance to abrasion
The loss of weight shall not be greater than 19g in accordance with ASTM D-56(75)
(h) Brittleness Temperature
Cold bend temperature shall not be greater than -300C in accordance with BS 104A() Cold flex temperature shall not be greater than +150C in accordance with BS 150B()
(i) Creeping Corrosion
Maximum penetration of corrosion of the wire core from a square cut end shall not be greater than 25 mm when the specimen has been immersed for hours in a 50% solution of HCI (hydrochloric acid 12 Be).
Table below lists the allowable variations to the Initial Properties after carrying out the following tests:-
(i) Salt Spray Test
As detailed in ASTM D117-73(79) for a test period of hours.
(ii) Exposure to Ultraviolet Light
As detailed in ASTM D-64(77) and ASTM F23-69(75) apparatus Type E for a test period of hours at 630C
(iii) Exposure at High Temperature
As detailed in ASTM D-67(74),(ISO 176-), and ASTM D-78 for a test period of 240 hours at C.
Gabion Mesh
The mesh shall be hexagonal woven mesh wherein the joints are formed by twisting each pair of wires through two full turns. The wire used is to be as specified in Specification.
The undisturbed size of the mesh shall be 100 mm by 120 mm (the shorter dimension being taken from centre to centre of the parallel twisted joins and the longer dimension, which is nominal, being between the ends of the coaxial twisted joins). The tightness of the twisted joins shall be such that a force of not less than 1.75 kN pulling on one wire is required to separate it from the other, provided each wire is prevented from turning and the wires and the applied force are all in the same plane.
The wire mesh shall have elasticity sufficient to permit elongation of the mesh equivalent to a minimum of 10% of the length of the section of mesh under test without reducing the diameter or tensile strength of individual wire strands to values less than those for a similar wire 0.3 mm smaller in diameter.
Selvedges
All edges of the gabions, diaphragms and end-panels, except as stated in Sub-clause 1.7 of this Specification, shall be selvedged with a wire of which the core diameter is 3.4mm. Where the selvedge is not woven integrally with the mesh but has to be fastened to the cut ends of the mesh, it shall be attached by binding the cut ends of the mesh about it so that a force of not less than 8.5 kN applied in the same plane as the mesh, at a point on the selvedge of a mesh sample of length one (1) metre is required to separate it from the mesh.
Diaphragms and End-Panels
The diaphragms and end-panels shall be selvedged on the top and vertical sides only. The end panels shall be attached by twisting the cut ends of the mesh wires at the bottom of the panel about the selvedge on the base of the gabions. Similarly, the diaphragms shall be attached by twisting the cut ends of the mesh to the twisted joins of the mesh of the gabions. In each case the force required to separate the panels from the base shall not be less than that required to break the mesh over the same length.
Binding and Connecting Wire
Sufficient binding and connecting wire shall be supplied with the gabions to perform all the wiring operations to be carried out in the construction of the gabion work. The diameter of wire shall be 2.20 millimetres.
Filling Material
Filling material shall consist of hard, durable stone of minimum dimension 100 millimetres and maximum dimension 250 millimetres and shall be tightly packed to give a minimum of voids. The top layer of material shall consist of selected smaller stone of not less than 100 millimetres minimum dimension.
Tolerances ( Wire Diamter, Gabions Dimensions)
A tolerance on the diameters of all wire of + 2½ per cent shall be permitted. The length of the gabions is subject to a tolerance of + 3 per cent and the width of gabions to a tolerance of + 25 millimetres. All other gabion dimensions are subject to a tolerance of + 3 per cent of the sizes stated in this Specification.
For fabrication of gabions, placement, filling and forming of river banks and aprons, go to next page.
For more Gabion Boxes For Saleinformation, please contact us. We will provide professional answers.